JCF/F

Home//JCF/F

  • Images
  • Slide 1
    Slide 2

  • Videos

  • FAQ
  • Frequently asked questions

    We are able to supply the correct replacement filters either individually or in packs of 10, together with replacement silicon tubing.  For more details please contact us.


    The tubing in the peristaltic pump housing flattens with wear over time, reducing the flow, and it eventually splits. It is recommended that this tube is replaced as soon as a reduced flow is observed.  Replacement tubes are available from Optimec.  For more details please contact us.


    The original halogen lamp fitment (soon to become unavailable) has now been superseded by a specially designed LED light engine which is now fitted as standard to all new Optimec instruments.  The LED provides a whiter light, sharper images, cooler operating temperature, and lower running costs.  The LED has been designed so it can be retrofitted by the customer to the majority of older instruments. Contact us.   


  • Specification
  • Dimensions: Height 589mm, Width 374mm, Depth 350mm
    Weight: 16kg
    Power consumption: 19 watts

    Diameter range: 6 – 16mm (up to 20mm available on JCF/20)
    Diameter accuracy: +/- 0.025mm
    Graticule increments: 0.1mm divisions (0.05mm graticule divisions available on JCF/S)
    Magnification diameter view: x17 approx

    BCOR range: 6.9-9.5mm
    BCOR accuracy: +/- 0.02mm
    Magnification BCOR view: x20 approx

    Consumables: Filters, tubing, 2 x 12V DC 6.6W LED light engines

    Calibration: BCOR test pieces, Diameter test pieces


  • Request a Quote
  • Your Name (required)

    Your Email (required)

    Product: JCFF

    Quantity:

    Your Message



      Lens Inspection

      Lens Diameter

      Lens BCOR

      Lens Thickness

      Saline Filtration (in built)


      The Optimec model JCF/F is almost identical to the JCF, both physically and in function. The instruments differ in one respect only. The JCF/F has a peristaltic pump mounted on the left hand side of the cabinet, which feeds saline back to the cell via a renewable cartridge filter. The pump system will remove particles from the saline to give a clear image of the contact lens in the wet cell. The pump can be switched off so that in the event of any pumping system failure the instrument can still be used for contact lens analysis.

      • Diameter Measurement
      • BCOR Measurement
      • Centre Thickness Check
      • Surface and Edge Inspection
      • In Built Saline Filtration